Sökresultat

Filtyp

Din sökning på "*" gav 565178 sökträffar

No title

Introduction The purpose of this study was to evaluate the safety and efficacy of PET and MRI guided re-irradiation of recurrent high-grade glioma (HGG) and to assess the impact of radiotherapy dose, fractionation and irradiated volume. Material and methods Patients with localized, recurrent HGG (grades III-IV) and no other treatment options were eligible for a prospective phase I trial. Gross tum

No title

BACKGROUND: Hypoxia and increased glycolytic activity of tumors are associated with poor prognosis. The purpose of this study was to investigate differences in radiotherapy (RT) dose painting based on the uptake of 2-deoxy-2-[(18) F]-fluorodeoxyglucose (FDG) and the proposed hypoxia tracer, copper(II)diacetyl-bis(N(4))-methylsemithiocarbazone (Cu-ATSM) using spontaneous clinical canine tumor model

No title

Objective. The aim of this study was to prospectively assess the development of 24 urinary, gastrointestinal and sexual symptoms in patients with prostate cancer (PCa) during and after image-guided volumetric modulated arc therapy (IG-VMAT). Material and methods. A total of 87 patients with PCa participated in this study. The patients were asked to complete a modified version of the Prostate Cance

No title

Results: The average gamma index failure rate (2% and 2 mm criteria) was < 0.01% with amplitude gating for all patients, and < 0.1% with phase gating and < 3.7% with MLC tracking for three of the four patients. One of the patients had an average failure rate of 15.1% with phase gating and 18.3% with MLC tracking.With no motion compensation, the average gamma index failure rate ranged from 7.1% to

No title

To determine visual outcome including the occurrence of radiation induced optic neuropathy (RION) as well as tumor control after fractionated stereotactic radiation therapy (FSRT) of benign anterior skull base meningiomas or pituitary adenomas. Thirty-nine patients treated with FSRT for anterior skull base meningiomas and 55 patients treated with FSRT for pituitary adenomas between January 1999 an

No title

Treatment of cervical cancer, one of the three most commonly diagnosed cancers worldwide, often relies on delineations of the tumour and metastases based on PET imaging using the contrast agent 18F-Fluorodeoxyglucose (FDG). We present a robust automatic algorithm for segmenting the gross tumour volume (GTV) and metastatic lymph nodes in such images. As the cervix is located next to the bladder and

No title

Background. Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that

No title

Background: 18F-FDG PET/CT (FDG PET/CT) used in radiotherapy planning for extra-cerebral malignancy may reveal metastases to distant sites that may affect the choice of therapy. Aim: To investigate the role of FDG PET/CT on treatment strategy changes induced by the use of PET/CT as part of the radiotherapy planning. ‘A major change of treatment strategy’ was defined as either including more lesion

No title

Purpose We evaluated the feasibility of treating patients with locally advanced non-small cell lung cancer (NSCLC) with pencil beam scanned intensity modulated proton therapy (IMPT) in breath-hold. Methods and Materials Fifteen NSCLC patients who had previously received 66 Gy in 33 fractions with image guided photon radiation therapy were included in the present simulation study. In addition to a

No title

Purpose Prostate motion during radiation therapy (ie, intrafraction motion) can cause unwanted loss of radiation dose to the prostate and increased dose to the surrounding organs at risk. A compact but general statistical description of this motion could be useful for simulation of radiation therapy delivery or margin calculations. We investigated whether prostate motion could be modeled with a ra

No title

Purpose The purpose of this study was to estimate the uncertainty in voluntary deep-inspiration breath-hold (DIBH) radiotherapy for locally advanced non-small cell lung cancer (NSCLC) patients. Methods Perpendicular fluoroscopic movies were acquired in free breathing (FB) and DIBH during a course of visually guided DIBH radiotherapy of nine patients with NSCLC. Patients had liquid markers injected

No title

Introduction:The breath-hold technique inter alia has been suggested to mitigate the detrimental effect of motion on pencil beam scanned (PBS) proton therapy dose distributions. The aim of this study was to evaluate the robustness of incident proton beam angles to day-to-day anatomical variations in breath-hold.Materials and methods: Single field PBS plans at five degrees increments in the trans

No title

Background: The purpose of this study was to examine visual outcome, endocrine function and tumor control in a prospective cohort of craniopharyngioma patients, treated with fractionated stereotactic radiation therapy (FSRT). Material and methods: Sixteen adult patients with craniopharyngiomas were eligible for analysis. They were treated with linear accelerator-based FSRT during 1999–2015. In all

No title

Background and purpose To evaluate the patterns of failure following clinical introduction of amino-acid O-(2-[18F]fluoroethyl)-L-tyrosine (FET)-PET-guided target definition for radiotherapy (RT) of glioblastoma patients. Materials and methods The first 66 consecutive patients with confirmed histology, scanned using FET-PET/CT and MRI were selected for evaluation. Chemo-radiotherapy was delivered

No title

Background and purpose We investigated the clinical applicability of a novel liquid fiducial marker (LFM) for image-guided pencil beam scanned (PBS) proton therapy (PBSPT) of locally advanced lung cancer (LALC). Materials and methods The relative proton stopping power (RSP) of the LFM was calculated and measured. Dose perturbations of the LFM and three solid markers, in a phantom, were measured. P

No title

Background and purpose Positron emission tomography (PET) provides quantitative metabolic information and potential biomarkers of treatment outcome. We aimed to determine the prognostic value of early 18F-fluoroethyl-tyrosine (18F-FET) PET scans acquired during re-irradiation for recurrent high-grade glioma (HGG). Material and methods A phase I clinical trial of re-irradiation of HGG was carried o

No title

Background: Radiotherapy (RT) in combination with androgen deprivation therapy (ADT) for prostate cancer (PCa) carries a risk of gastrointestinal (GI) and genitourinary toxicity, which might affect the quality of life (QoL). The purpose of this study was to assess the QoL in patients with PCa before, during and after radiotherapy (RT) and to compare the QoL 1 year after RT to a normal population.

No title

Purpose The safe clinical implementation of pencil beam scanning (PBS) proton therapy for lung tumors is complicated by the delivery uncertainties caused by breathing motion. The purpose of this feasibility study was to investigate whether a voluntary breath-hold technique could limit the delivery uncertainties resulting from interfractional motion. Methods and Materials Data from 15 patients with

No title

We present a fully automated generative method for simultaneous brain tumor and organs-at-risk segmentation in multi-modal magnetic resonance images. The method combines an existing whole-brain segmentation technique with a spatial tumor prior, which uses convolutional restricted Boltzmann machines to model tumor shape. The method is not tuned to any specific imaging protocol and can simultaneousl

No title

Development of safe and efficient radiotherapy routines requires quantification of the delivered absorbed dose to the cancer tissue in individual patients. In vivo dosimetry can provide accurate information about the absorbed dose delivered during treatment. In the current study, a novel silver-nanosensor formulation based on poly(vinylpyrrolidinone)-coated silver nanoparticles formulated in a gel