The effects of electrode thickness, electrolyte filling and current collector geometry on the performance of MCFC cathodes are investigated by using a steady state mathematical model. A two-dimensional pseudo-homogeneous model for the three-phase system in the cathode is used, which includes the polarisation curves from the heterogeneous agglomerate model[1] as local source functions. The model ta