Influence of temperature, particle size and humidity on the gypsum dehydration process. Investigations in a Cahn-thermobalance
The aim of the present work was to compare natural and chemical gypsums with respect to dehydration rate and to investigate the influence of air temperature, particle size and air humidity. No difference in calcination rate could be observed between natural and FGD-gypsum. However the small samples did not permit tests of setting times or simulation of the mixer behaviour. The calcination rate was