Evaluation of different coatings of the tibial tray in uncemented total knee arthroplasty. A randomized controlled trial with 5 years follow-up with RSA and DEXA
Background: Regenerex® is a porous titanium construct with a 3D interconnecting pore structure and biomechanical characteristics close to that of normal trabecular bone. This study aimed to compare the Regenerex (VR) to the non-interconnecting pore structure Porous Plasma Spray (VP) on tibial implants for total knee arthroplasty (TKA) at 5 years. Methods: We enrolled and randomized 61 patients (me